Accuracy @ 25°C:
Types J and K: ±0.5% rdg or ±1.0°C
(1.8°F), whichever is greater
Types T, E, and N: ±0.5% rdg or
±2.0°C (3.6°F), whichever is greater
Types R, S, B and C: ±0.5% FS
Resolution: 1°C/1°F
Sensor Connection: Screw terminals
Model UWXL-24-RTD
Input: Pt100 RTD; 0.00385 or 0.00392
curve, software selectable
Measurement Range:
Pt100, 0.00385: -200 to 850°C
(-328 to 1562°F)
Pt100, 0.00392: -100 to 457°C
(-148 to 854°F)
Accuracy: ±0.5°C (1.0°F)
Resolution: 1°C/1°F
Sensor Connection: Screw
terminals
Model UWXL-24-IR-1
Temperature Range: -18 to 538°C
(0 to 1000°F)
Accuracy: ±2% rdg or 2.2°C (4°F),
whichever is greater; @ 22°C (72°F)
ambient temperature and emissivity
≥0.95
Optical Field of View: 6:1 (distance/
spot size)
Sensor Head Cable Extension:
Up to 15 m (50’) total
Repeatability: ±1% rdg
Spectral Response: 5 to 14 microns
Response Time: 100 ms (0 to 63% of
final value)
Emissivity: 0.1 to 1.00, adjustable
Common Specifications
Computer Interface: USB
Transmit Sample Rate: Programmable
from 2 second to 120 second
Radio Frequency (RF) Transceiver
Carrier: ISM 2.4 GHz, direct sequence
spread spectrum, (2.450 to 2.490 GHz–
12 RF channels)
RF Output Power: 18 dBm (63 mW)
Range of RF Link: Up to 450 m (1500')
outdoor line of sight; up to 90 m (300')
indoor/urban
RF Data Packet Standard: IEEE
802.15.4, open communication
architecture
Software (Included Free): Requires
Windows
®
2000, XP or Vista (32 bit)
operating system
Power: One 3.6V, Lithium C Cell
(included)
Battery Life (Typical): 3 years;
at 1 sample/minute reading rate @ 25°C
Operating Temperature: -10 to 70°C
(14 to 158°F)
Storage Temperature: -40 to 80°C
(-40 to 176°F)
Model UWXL-24-TC
Input: J, K, T, E, R, S, B, C or N
thermocouple, software selectable
Measurement Range:
J: -100 to 760°C (-148 to 1400°F)
K: -100 to 1260°C (-148 to 2300°F)
T: -200 to 400°C (-328 to 752°F)
E: -200 to 1000°C (-328 to 1832°F)
R: 260 to 1760°C (500 to 3200°F)
S: 260 to 1760°C (500 to 3200°F)
B: 870 to 1820°C (1598 to 3308°F)
C: 0 to 2315°C (32 to 4200°F)
N: -100 to 1260°C (-148 to 2300°F)
Operating Ambient:
Sensor Head: 0 to 70°C (32 to158°F)
Sensor Head (-HT Model): 0 to 85°C
(32 to 185°F)
Sensor head with OS100-WC
(Water Cooling Jacket): 0 to 200°C
(32 to 392°F)
Relative Humidity: Less than
95% RH, non-condensing
OS100-WC Water Flow Rate:
0.25 GPM, room temperature
Thermal Shock: About 30 minute
for 25°C (77°F) abrupt ambient
temperature change
Warm-Up Period: 3 minutes
OS100-AP Air Flow Rate: 1 CFM
(0.5 L/s) (1 x 2.5")
OS100-LA Laser Sight
Accessory
Wavelength (Color): 630 to 670 nm (red)
Operating Distance (Laser Dot):
Up to 9.1 m (30')
Max Output Optical Power: Less
than 1 mW @ -6°C (22°F) ambient
temperature
European Classification: Class 2,
EN60825-1/11.2001
Max Operating Current: 45 mA
@ 3 Vdc
FDA Classification: Complies with
21 CFR 1040.10, Class II laser product
Beam Diameter: 5 mm (0.20")
Beam Divergence: <2 mrad
Operating Ambient: 0 to 50°C (32 to
122°F); <95% RH, non-condensing
Power Switch: On/off slide switch on
the battery pack
Power Indicator: Red LED
Power: Battery pack, 3 Vdc (consists
of two 1.5 Vdc “AA” lithium batteries,
included)
Thermocouple and RTD
models feature screw
terminal connections that
allow you to connect a wide
range of sensors and probes.
Models
with intergral probes
are available contact factory.
Transmitter model
UWXL-24-RH-RPI.
Temperature transmitter models
UWXL-TC-24, UWXL-RTD.
Humidity/temperature
sensor included.
UWXL-IR-1 features a remotely mounted
sensor head to measure non-contact
infrared temperature.
Infrared
sensor head
included.
UWXL-RH features a detachable
combination humidity/temperature
sensor that can be remotely mounted.
Transmitter model